全面检测
Simulate the quality inspection of products in operating, transportation, and storage environment.
多样化的体验方式
You can choose demo test for remote experience, or test report to get the results directly.
实际测试情况
Simulate the network conditions of customers to evaluate how products work in real scenarios.
EMC Test
静电放电抗扰度测试
This section outlines the procedures for validating the system or device’s compliance with ESD standards, ensuring reliable and secure operation in ESD-prone environments. It focuses on identifying and mitigating potential vulnerabilities in design, layout, grounding, shielding, or protective measures.Test Standard:EN 50121-4
Test Way:EN 61000-4-2

电气快速瞬态/爆破抗扰度测试
Electrical fast transient/burst immunity testing applies rapid low-energy pulses (bursts) to evaluate a system or device’s resilience to transient electrical disturbances.Test Standard: EN 50121-4
Test Way: EN 61000-4-4

浪涌抗扰度测试
Surge immunity testing evaluates a system or device’s resistance to high-energy, low-frequency pulses (surges) caused by events such as lightning, load switching, or short circuits, which induce sudden voltage or current fluctuations in power or data lines.Test Standard: EN 50121-4
Test Way: EN 61000-4-5

Electric Characteristics Test
绝缘电阻测试
The Insulation Resistance Test assesses the integrity of insulation in electrical systems, devices, or components by applying a high DC voltage (typically 100V to 10kV) and measuring the resistance between conductors or between conductors and ground, ensuring insulation quality and reliability.Test Standard: TB/T 1447
Test Way: TB/T 1447

耐压测试
The Voltage Withstand Test evaluates insulation quality in electrical systems, devices, or components by applying elevated AC or DC voltages and measuring leakage current between conductors or to ground, ensuring insulation integrity and reliability.Test Standard: EN 50124-1
Test Way: EN 50124-1

接地连续性测试
The Earthing Continuity Test measures the resistance of protective grounding conductors in electrical apparatus to validate low-impedance connections between power supply plugs and accessible conductive components, ensuring effective fault current pathways.Test Standard: EN60950-1
Test Way: EN60950-1